{"product_id":"co2-fractional-laser-machine","title":"Co2 Fractional Laser Machine","description":"\u003ch3 data-section-id=\"1k8uwy3\" data-start=\"70\" data-end=\"93\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-start=\"94\" data-end=\"475\"\u003eThe CO₂ Fractional Laser System is an advanced aesthetic and dermatological device designed to perform precise, controlled laser-based procedures. It operates using a carbon dioxide laser with a wavelength of \u003cstrong data-start=\"303\" data-end=\"316\"\u003e10,600 nm\u003c\/strong\u003e, which is highly absorbed by human tissue regardless of skin tone. This characteristic allows for consistent interaction with targeted areas during treatment.\u003c\/p\u003e\n\u003cp data-start=\"477\" data-end=\"681\"\u003eThe system emits a micropulsed laser beam that can be adjusted to act at a highly controlled scale, enabling operators to define treatment depth and coverage according to specific procedural requirements.\u003c\/p\u003e\n\u003chr data-start=\"683\" data-end=\"686\"\u003e\n\u003ch3 data-section-id=\"1ruj8lp\" data-start=\"688\" data-end=\"711\"\u003eOperating Principle\u003c\/h3\u003e\n\u003ch4 data-start=\"713\" data-end=\"749\"\u003eFractional CO₂ Laser Technology\u003c\/h4\u003e\n\u003cp data-start=\"750\" data-end=\"972\"\u003eThe device utilizes fractional laser technology combined with photothermal effects. The emitted laser energy is delivered in micro-pulses to targeted tissue, generating controlled thermal interaction. This process enables:\u003c\/p\u003e\n\u003cul data-start=\"974\" data-end=\"1147\"\u003e\n\u003cli data-section-id=\"18m3quw\" data-start=\"974\" data-end=\"1024\"\u003ePrecise ablation and micro-perforation of tissue\u003c\/li\u003e\n\u003cli data-section-id=\"ox0njy\" data-start=\"1025\" data-end=\"1077\"\u003eControlled thermal stimulation of the treated area\u003c\/li\u003e\n\u003cli data-section-id=\"1bsex7z\" data-start=\"1078\" data-end=\"1147\"\u003eMinimal impact on surrounding tissue due to focused energy delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1149\" data-end=\"1359\"\u003eThe laser operates with stable and uniform energy output, ensuring consistency during procedures. Additionally, a red semiconductor guide beam is integrated to assist with accurate positioning during operation.\u003c\/p\u003e\n\u003chr data-start=\"1361\" data-end=\"1364\"\u003e\n\u003ch3 data-section-id=\"1qads5m\" data-start=\"1366\" data-end=\"1398\"\u003eTissue Interaction Mechanism\u003c\/h3\u003e\n\u003cp data-start=\"1400\" data-end=\"1502\"\u003eThe CO₂ laser produces both thermal and electromagnetic effects, which are used in procedures such as:\u003c\/p\u003e\n\u003cul data-start=\"1504\" data-end=\"1633\"\u003e\n\u003cli data-section-id=\"qr1g8\" data-start=\"1504\" data-end=\"1538\"\u003eNon-blood or low-blood cutting\u003c\/li\u003e\n\u003cli data-section-id=\"1hyqwnz\" data-start=\"1539\" data-end=\"1563\"\u003eTissue cauterization\u003c\/li\u003e\n\u003cli data-section-id=\"19onmgg\" data-start=\"1564\" data-end=\"1595\"\u003eVaporization (gasification)\u003c\/li\u003e\n\u003cli data-section-id=\"qv755g\" data-start=\"1596\" data-end=\"1633\"\u003eMicro-level surgical applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1635\" data-end=\"1904\"\u003eDuring application, optical-thermal interaction induces biological responses in the treated area, including stimulation of cellular activity and structural tissue processes. The system is designed to allow controlled exfoliation and regeneration at the treated surface.\u003c\/p\u003e\n\u003chr data-start=\"1906\" data-end=\"1909\"\u003e\n\u003ch3 data-section-id=\"16874bi\" data-start=\"1911\" data-end=\"1943\"\u003eVaginal Treatment Technology\u003c\/h3\u003e\n\u003ch4 data-start=\"1945\" data-end=\"1970\"\u003eFunctional Principle\u003c\/h4\u003e\n\u003cp data-start=\"1971\" data-end=\"2105\"\u003eThe system incorporates a fractional CO₂ laser mode designed for procedures involving vaginal tissue. The laser energy interacts with:\u003c\/p\u003e\n\u003cul data-start=\"2107\" data-end=\"2162\"\u003e\n\u003cli data-section-id=\"uoirbo\" data-start=\"2107\" data-end=\"2125\"\u003eVaginal mucosa\u003c\/li\u003e\n\u003cli data-section-id=\"8v86mh\" data-start=\"2126\" data-end=\"2144\"\u003eLamina propria\u003c\/li\u003e\n\u003cli data-section-id=\"h53bg9\" data-start=\"2145\" data-end=\"2162\"\u003eMuscle layers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2164\" data-end=\"2366\"\u003eThis interaction stimulates fibroblast activity and affects collagen and elastic fiber structure. The process involves controlled thermal stimulation and microvascular interaction at the treatment site.\u003c\/p\u003e\n\u003ch4 data-start=\"2368\" data-end=\"2388\"\u003eTissue Response\u003c\/h4\u003e\n\u003cp data-start=\"2389\" data-end=\"2449\"\u003eLaser application at the microvascular level contributes to:\u003c\/p\u003e\n\u003cul data-start=\"2451\" data-end=\"2571\"\u003e\n\u003cli data-section-id=\"1c72i27\" data-start=\"2451\" data-end=\"2485\"\u003eIncreased localized blood flow\u003c\/li\u003e\n\u003cli data-section-id=\"wfjn9t\" data-start=\"2486\" data-end=\"2526\"\u003eEnhanced cellular metabolic activity\u003c\/li\u003e\n\u003cli data-section-id=\"10pzw4z\" data-start=\"2527\" data-end=\"2571\"\u003eActivation of tissue response mechanisms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2573\" data-end=\"2686\"\u003eThe system is designed to influence structural characteristics of the tissue through controlled thermal exposure.\u003c\/p\u003e\n\u003chr data-start=\"2688\" data-end=\"2691\"\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2693\" data-end=\"2709\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2711\" data-end=\"2775\"\u003eThe CO₂ Fractional Laser System is used in procedures involving:\u003c\/p\u003e\n\u003cul data-start=\"2777\" data-end=\"2958\"\u003e\n\u003cli data-section-id=\"14h50z0\" data-start=\"2777\" data-end=\"2817\"\u003eVaginal tissue tightening procedures\u003c\/li\u003e\n\u003cli data-section-id=\"fqhujp\" data-start=\"2818\" data-end=\"2863\"\u003eSupport of lubrication-related treatments\u003c\/li\u003e\n\u003cli data-section-id=\"1lpdy0t\" data-start=\"2864\" data-end=\"2910\"\u003eProcedures targeting tissue responsiveness\u003c\/li\u003e\n\u003cli data-section-id=\"1yk5nnt\" data-start=\"2911\" data-end=\"2958\"\u003eGeneral vaginal tissue condition management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2960\" data-end=\"3066\"\u003e\u003cem data-start=\"2960\" data-end=\"3066\"\u003eNote: Applications are based on device functionality and intended use. No specific outcomes are implied.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"3068\" data-end=\"3071\"\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"3073\" data-end=\"3101\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3103\" data-end=\"3937\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3103\" data-end=\"3132\"\u003e\n\u003ctr data-start=\"3103\" data-end=\"3132\"\u003e\n\u003cth data-start=\"3103\" data-end=\"3115\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"3115\" data-end=\"3132\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3160\" data-end=\"3937\"\u003e\n\u003ctr data-start=\"3160\" data-end=\"3212\"\u003e\n\u003ctd data-start=\"3160\" data-end=\"3177\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3162\" data-end=\"3176\"\u003eLaser Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3177\" data-end=\"3212\"\u003eCarbon Dioxide Fractional Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3213\" data-end=\"3249\"\u003e\n\u003ctd data-start=\"3213\" data-end=\"3236\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3215\" data-end=\"3235\"\u003eLaser Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3236\" data-end=\"3249\"\u003e10,600 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3250\" data-end=\"3292\"\u003e\n\u003ctd data-start=\"3250\" data-end=\"3268\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3252\" data-end=\"3267\"\u003eLaser Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3268\" data-end=\"3292\"\u003e30W – 60W (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3293\" data-end=\"3348\"\u003e\n\u003ctd data-start=\"3293\" data-end=\"3321\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3295\" data-end=\"3320\"\u003eLight Delivery System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3321\" data-end=\"3348\"\u003e7-joint articulated arm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3349\" data-end=\"3387\"\u003e\n\u003ctd data-start=\"3349\" data-end=\"3370\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3351\" data-end=\"3369\"\u003ePulse Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3370\" data-end=\"3387\"\u003e100 – 5000 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3388\" data-end=\"3419\"\u003e\n\u003ctd data-start=\"3388\" data-end=\"3404\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3390\" data-end=\"3403\"\u003eSpot Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3404\" data-end=\"3419\"\u003eSingle mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3420\" data-end=\"3461\"\u003e\n\u003ctd data-start=\"3420\" data-end=\"3450\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3422\" data-end=\"3449\"\u003eBeam Diameter (Focused)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3450\" data-end=\"3461\"\u003e0.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3462\" data-end=\"3490\"\u003e\n\u003ctd data-start=\"3462\" data-end=\"3479\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3464\" data-end=\"3478\"\u003eFocal Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3479\" data-end=\"3490\"\u003e0.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3491\" data-end=\"3537\"\u003e\n\u003ctd data-start=\"3491\" data-end=\"3510\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3493\" data-end=\"3509\"\u003eOutput Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3510\" data-end=\"3537\"\u003eUltra Pulse, Fractional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3538\" data-end=\"3604\"\u003e\n\u003ctd data-start=\"3538\" data-end=\"3559\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3540\" data-end=\"3558\"\u003eScanning Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3559\" data-end=\"3604\"\u003eSequential, Random, Parallel (switchable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3605\" data-end=\"3688\"\u003e\n\u003ctd data-start=\"3605\" data-end=\"3627\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3607\" data-end=\"3626\"\u003eScanning Shapes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3627\" data-end=\"3688\"\u003eTriangle, square, rectangle, round, oval, hexagon, linear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3689\" data-end=\"3732\"\u003e\n\u003ctd data-start=\"3689\" data-end=\"3713\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3691\" data-end=\"3712\"\u003eMax Scanning Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3713\" data-end=\"3732\"\u003e≤ 20 mm × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3733\" data-end=\"3778\"\u003e\n\u003ctd data-start=\"3733\" data-end=\"3747\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3735\" data-end=\"3746\"\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3747\" data-end=\"3778\"\u003e8.4-inch color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3779\" data-end=\"3831\"\u003e\n\u003ctd data-start=\"3779\" data-end=\"3800\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3781\" data-end=\"3799\"\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3800\" data-end=\"3831\"\u003eAir cooling + water cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3832\" data-end=\"3894\"\u003e\n\u003ctd data-start=\"3832\" data-end=\"3851\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3834\" data-end=\"3850\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3851\" data-end=\"3894\"\u003eAC 230V ±10%, 50Hz \/ AC 110V ±10%, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3895\" data-end=\"3937\"\u003e\n\u003ctd data-start=\"3895\" data-end=\"3911\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3897\" data-end=\"3910\"\u003eWork Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3911\" data-end=\"3937\"\u003eIntermittent operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3939\" data-end=\"3942\"\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"3944\" data-end=\"3960\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"3962\" data-end=\"4296\"\u003e\n\u003cli data-section-id=\"1390c4l\" data-start=\"3962\" data-end=\"4016\"\u003eAdjustable fractional scanning patterns and shapes\u003c\/li\u003e\n\u003cli data-section-id=\"hgvkfx\" data-start=\"4017\" data-end=\"4077\"\u003eDual cooling system (air and water) for device stability\u003c\/li\u003e\n\u003cli data-section-id=\"102uy7o\" data-start=\"4078\" data-end=\"4130\"\u003eMultiple output modes for procedural flexibility\u003c\/li\u003e\n\u003cli data-section-id=\"8zlpnw\" data-start=\"4131\" data-end=\"4188\"\u003eHigh-precision beam control with small focal diameter\u003c\/li\u003e\n\u003cli data-section-id=\"18fdvjf\" data-start=\"4189\" data-end=\"4243\"\u003eArticulated arm system for accurate laser delivery\u003c\/li\u003e\n\u003cli data-section-id=\"hpd4bl\" data-start=\"4244\" data-end=\"4296\"\u003eIntegrated user interface via color touch screen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4298\" data-end=\"4301\"\u003e\n\u003ch3 data-section-id=\"1crk1xq\" data-start=\"4303\" data-end=\"4336\"\u003eWhat Does the System Include?\u003c\/h3\u003e\n\u003cul data-start=\"4338\" data-end=\"4521\"\u003e\n\u003cli data-section-id=\"1rn3xk5\" data-start=\"4338\" data-end=\"4372\"\u003eCO₂ fractional laser main unit\u003c\/li\u003e\n\u003cli data-section-id=\"1nxv55b\" data-start=\"4373\" data-end=\"4408\"\u003eArticulated arm delivery system\u003c\/li\u003e\n\u003cli data-section-id=\"16paboj\" data-start=\"4409\" data-end=\"4442\"\u003eTouchscreen control interface\u003c\/li\u003e\n\u003cli data-section-id=\"1p7meyr\" data-start=\"4443\" data-end=\"4489\"\u003eIntegrated cooling systems (air and water)\u003c\/li\u003e\n\u003cli data-section-id=\"1qqh92e\" data-start=\"4490\" data-end=\"4521\"\u003eRed light positioning guide\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SKIN MAX TECHNOLOGY MIAMI, FL","offers":[{"title":"Default Title","offer_id":42839550296162,"sku":null,"price":8900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/3426\/8258\/files\/Co2FractionalLaserMachine.png?v=1777388826","url":"https:\/\/skinmaxtech.com\/products\/co2-fractional-laser-machine","provider":"SKIN MAX TECHNOLOGY MIAMI, FL","version":"1.0","type":"link"}