{"product_id":"360-angel-max-cryolipolysis","title":"360 Angel Max Cryolipolysis","description":"\u003ch2 data-section-id=\"hozrev\" data-start=\"0\" data-end=\"42\"\u003e360 Cryolipolysis Technology – Overview\u003c\/h2\u003e\n\u003cp data-start=\"44\" data-end=\"319\"\u003e\u003cstrong data-start=\"44\" data-end=\"65\"\u003e360 Cryolipolysis\u003c\/strong\u003e is a body contouring technology designed to apply controlled cooling and heating across targeted areas using multi-directional applicators. It operates with a full 360-degree approach, allowing uniform temperature distribution around the treatment zone.\u003c\/p\u003e\n\u003chr data-start=\"321\" data-end=\"324\"\u003e\n\u003ch2 data-section-id=\"n0dh77\" data-start=\"326\" data-end=\"356\"\u003eHow 360 Cryolipolysis Works\u003c\/h2\u003e\n\u003cp data-start=\"358\" data-end=\"444\"\u003eThe system combines \u003cstrong data-start=\"378\" data-end=\"408\"\u003ecooling and heating cycles\u003c\/strong\u003e within a defined temperature range:\u003c\/p\u003e\n\u003cul data-start=\"446\" data-end=\"500\"\u003e\n\u003cli data-section-id=\"mev14b\" data-start=\"446\" data-end=\"474\"\u003eCooling: down to \u003cstrong data-start=\"465\" data-end=\"474\"\u003e-10°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16m49nq\" data-start=\"475\" data-end=\"500\"\u003eHeating: up to \u003cstrong data-start=\"492\" data-end=\"500\"\u003e45°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"502\" data-end=\"642\"\u003eThese temperature variations are applied through programmable cycles, allowing flexible parameter adjustment depending on operational needs.\u003c\/p\u003e\n\u003cp data-start=\"644\" data-end=\"913\"\u003eThe technology focuses on \u003cstrong data-start=\"670\" data-end=\"701\"\u003esubcutaneous tissue cooling\u003c\/strong\u003e, where lipid-rich cells are exposed to low temperatures. This process can lead to crystallization within these cells, followed by gradual breakdown and natural elimination through the body’s metabolic processes.\u003c\/p\u003e\n\u003chr data-start=\"915\" data-end=\"918\"\u003e\n\u003ch2 data-section-id=\"706w28\" data-start=\"920\" data-end=\"942\"\u003eKey System Features\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1kzjqqb\" data-start=\"944\" data-end=\"976\"\u003eAdvanced Temperature Control\u003c\/h3\u003e\n\u003cul data-start=\"977\" data-end=\"1134\"\u003e\n\u003cli data-section-id=\"1jjthcv\" data-start=\"977\" data-end=\"1023\"\u003eReal-time \u003cstrong data-start=\"989\" data-end=\"1023\"\u003edynamic temperature monitoring\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qissu6\" data-start=\"1024\" data-end=\"1088\"\u003eAutomatic \u003cstrong data-start=\"1036\" data-end=\"1063\"\u003ethermostatic regulation\u003c\/strong\u003e for consistent operation\u003c\/li\u003e\n\u003cli data-section-id=\"1eqi0hp\" data-start=\"1089\" data-end=\"1134\"\u003eBuilt-in \u003cstrong data-start=\"1100\" data-end=\"1134\"\u003efrost protection safety module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"10k1z15\" data-start=\"1136\" data-end=\"1168\"\u003eIntelligent Operating System\u003c\/h3\u003e\n\u003cul data-start=\"1169\" data-end=\"1352\"\u003e\n\u003cli data-section-id=\"1xtkzrg\" data-start=\"1169\" data-end=\"1222\"\u003eIndependent power supply for \u003cstrong data-start=\"1200\" data-end=\"1222\"\u003estable performance\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12xxswq\" data-start=\"1223\" data-end=\"1303\"\u003e\n\u003cstrong data-start=\"1225\" data-end=\"1260\"\u003eAutomatic accessory recognition\u003c\/strong\u003e with error alerts to prevent incorrect use\u003c\/li\u003e\n\u003cli data-section-id=\"xc419t\" data-start=\"1304\" data-end=\"1352\"\u003eProgrammable settings for customized operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"z6ddth\" data-start=\"1354\" data-end=\"1382\"\u003eEfficient Cooling System\u003c\/h3\u003e\n\u003cul data-start=\"1383\" data-end=\"1576\"\u003e\n\u003cli data-section-id=\"h7gqwu\" data-start=\"1383\" data-end=\"1450\"\u003eHigh-flow \u003cstrong data-start=\"1395\" data-end=\"1419\"\u003ewater cooling module\u003c\/strong\u003e for effective heat dissipation\u003c\/li\u003e\n\u003cli data-section-id=\"2a6keg\" data-start=\"1451\" data-end=\"1523\"\u003eAutomatic water circulation (1-minute cycle) after startup or shutdown\u003c\/li\u003e\n\u003cli data-section-id=\"zwqcns\" data-start=\"1524\" data-end=\"1576\"\u003eSafety shutdown if abnormal water flow is detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"4vyc02\" data-start=\"1578\" data-end=\"1609\"\u003eErgonomic Applicator Design\u003c\/h3\u003e\n\u003cul data-start=\"1610\" data-end=\"1804\"\u003e\n\u003cli data-section-id=\"18lxh1p\" data-start=\"1610\" data-end=\"1673\"\u003e\n\u003cstrong data-start=\"1612\" data-end=\"1644\"\u003eSoft silicone freezing heads\u003c\/strong\u003e designed for contact comfort\u003c\/li\u003e\n\u003cli data-section-id=\"1gphbjo\" data-start=\"1674\" data-end=\"1739\"\u003e\n\u003cstrong data-start=\"1676\" data-end=\"1716\"\u003e360° surrounding cooling applicators\u003c\/strong\u003e for full-area coverage\u003c\/li\u003e\n\u003cli data-section-id=\"8ooqy3\" data-start=\"1740\" data-end=\"1804\"\u003eMultiple applicator sizes (8 handles) for different body areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1806\" data-end=\"1809\"\u003e\n\u003ch2 data-section-id=\"g8ldjs\" data-start=\"1811\" data-end=\"1848\"\u003eApplicators and Treatment Coverage\u003c\/h2\u003e\n\u003cp data-start=\"1850\" data-end=\"1969\"\u003eThe device includes \u003cstrong data-start=\"1870\" data-end=\"1904\"\u003e8 interchangeable cryo handles\u003c\/strong\u003e, designed to adapt to various body contours and treatment zones.\u003c\/p\u003e\n\u003cp data-start=\"1971\" data-end=\"2001\"\u003e\u003cstrong data-start=\"1971\" data-end=\"2001\"\u003eExample: Small Cryo Handle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2002\" data-end=\"2095\"\u003e\n\u003cli data-section-id=\"6xtpm1\" data-start=\"2002\" data-end=\"2042\"\u003eSuitable for \u003cstrong data-start=\"2017\" data-end=\"2042\"\u003elonger vertical areas\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10wnkf\" data-start=\"2043\" data-end=\"2095\"\u003eCommonly used for:\n\u003cul data-start=\"2066\" data-end=\"2095\"\u003e\n\u003cli data-section-id=\"1enmrdy\" data-start=\"2066\" data-end=\"2075\"\u003eAbdomen\u003c\/li\u003e\n\u003cli data-section-id=\"1y1fmhh\" data-start=\"2078\" data-end=\"2086\"\u003eFlanks\u003c\/li\u003e\n\u003cli data-section-id=\"1j435l1\" data-start=\"2089\" data-end=\"2095\"\u003eArms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2097\" data-end=\"2210\"\u003eThe 360° applicator design enables \u003cstrong data-start=\"2132\" data-end=\"2153\"\u003efull-area contact\u003c\/strong\u003e, allowing consistent exposure across the treatment zone.\u003c\/p\u003e\n\u003chr data-start=\"2212\" data-end=\"2215\"\u003e\n\u003ch2 data-section-id=\"288c8e\" data-start=\"2217\" data-end=\"2240\"\u003eOperational Workflow\u003c\/h2\u003e\n\u003cp data-start=\"2242\" data-end=\"2279\"\u003eA typical operation process includes:\u003c\/p\u003e\n\u003col data-start=\"2281\" data-end=\"2529\"\u003e\n\u003cli data-section-id=\"1v11sau\" data-start=\"2281\" data-end=\"2322\"\u003eClient assessment and history review\u003c\/li\u003e\n\u003cli data-section-id=\"r19nui\" data-start=\"2323\" data-end=\"2361\"\u003eIdentification of treatment areas\u003c\/li\u003e\n\u003cli data-section-id=\"1b85mm4\" data-start=\"2362\" data-end=\"2412\"\u003eApplication of protective antifreeze membrane\u003c\/li\u003e\n\u003cli data-section-id=\"faks3x\" data-start=\"2413\" data-end=\"2455\"\u003eDevice setup and parameter adjustment\u003c\/li\u003e\n\u003cli data-section-id=\"map7xf\" data-start=\"2456\" data-end=\"2485\"\u003eStart of treatment cycle\u003c\/li\u003e\n\u003cli data-section-id=\"1x5c2fu\" data-start=\"2486\" data-end=\"2529\"\u003eCompletion and post-process evaluation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"2531\" data-end=\"2534\"\u003e\n\u003ch2 data-section-id=\"woua9t\" data-start=\"2536\" data-end=\"2571\"\u003eTreatment Duration and Operation\u003c\/h2\u003e\n\u003cul data-start=\"2573\" data-end=\"2773\"\u003e\n\u003cli data-section-id=\"1oy9z1y\" data-start=\"2573\" data-end=\"2630\"\u003eEach session typically lasts \u003cstrong data-start=\"2604\" data-end=\"2630\"\u003e35–45 minutes per area\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x8nd6v\" data-start=\"2631\" data-end=\"2699\"\u003eDual-channel design allows \u003cstrong data-start=\"2660\" data-end=\"2699\"\u003esimultaneous operation on two areas\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ml1xwl\" data-start=\"2700\" data-end=\"2773\"\u003eAdjustable intervals between sessions depending on operational protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2775\" data-end=\"2778\"\u003e\n\u003ch2 data-section-id=\"w8fnad\" data-start=\"2780\" data-end=\"2811\"\u003eSystem Technology Highlights\u003c\/h2\u003e\n\u003cul data-start=\"2813\" data-end=\"3070\"\u003e\n\u003cli data-section-id=\"rkg726\" data-start=\"2813\" data-end=\"2895\"\u003e\n\u003cstrong data-start=\"2815\" data-end=\"2851\"\u003ePre-heating and cooling sequence\u003c\/strong\u003e to support gradual temperature transition\u003c\/li\u003e\n\u003cli data-section-id=\"1sovsfj\" data-start=\"2896\" data-end=\"2960\"\u003e\n\u003cstrong data-start=\"2898\" data-end=\"2929\"\u003eVacuum-assisted applicators\u003c\/strong\u003e for targeted area engagement\u003c\/li\u003e\n\u003cli data-section-id=\"jxyx7v\" data-start=\"2961\" data-end=\"3025\"\u003e\n\u003cstrong data-start=\"2963\" data-end=\"2986\"\u003eDual-channel system\u003c\/strong\u003e for increased operational efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"loz5q0\" data-start=\"3026\" data-end=\"3070\"\u003e\u003cstrong data-start=\"3028\" data-end=\"3070\"\u003eAutomated safety monitoring and alerts\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3072\" data-end=\"3075\"\u003e\n\u003ch2 data-section-id=\"164os46\" data-start=\"3077\" data-end=\"3100\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cp data-start=\"3102\" data-end=\"3173\"\u003eThis equipment is commonly used in professional aesthetic settings for:\u003c\/p\u003e\n\u003cul data-start=\"3175\" data-end=\"3347\"\u003e\n\u003cli data-section-id=\"6b5jaf\" data-start=\"3175\" data-end=\"3215\"\u003eLocalized body contouring procedures\u003c\/li\u003e\n\u003cli data-section-id=\"1fzj30e\" data-start=\"3216\" data-end=\"3267\"\u003eAreas with \u003cstrong data-start=\"3229\" data-end=\"3265\"\u003econcentrated subcutaneous tissue\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k67ozb\" data-start=\"3268\" data-end=\"3301\"\u003ePostpartum body care routines\u003c\/li\u003e\n\u003cli data-section-id=\"1sk8c76\" data-start=\"3302\" data-end=\"3347\"\u003eGeneral non-invasive aesthetic treatments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3349\" data-end=\"3352\"\u003e\n\u003ch2 data-section-id=\"4m82gu\" data-start=\"3354\" data-end=\"3384\"\u003ePost-Process Considerations\u003c\/h2\u003e\n\u003cul data-start=\"3386\" data-end=\"3598\"\u003e\n\u003cli data-section-id=\"whnebn\" data-start=\"3386\" data-end=\"3454\"\u003eThe procedure is \u003cstrong data-start=\"3405\" data-end=\"3421\"\u003enon-invasive\u003c\/strong\u003e, with no surgical intervention\u003c\/li\u003e\n\u003cli data-section-id=\"8boaca\" data-start=\"3455\" data-end=\"3529\"\u003eTemporary skin responses such as redness or mild sensitivity may occur\u003c\/li\u003e\n\u003cli data-section-id=\"109bqaw\" data-start=\"3530\" data-end=\"3598\"\u003eNormal daily activities can typically continue after the session\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3600\" data-end=\"3603\"\u003e\n\u003ch2 data-section-id=\"ak1jgz\" data-start=\"3605\" data-end=\"3635\"\u003eWhat the Equipment Includes\u003c\/h2\u003e\n\u003cul data-start=\"3637\" data-end=\"3792\"\u003e\n\u003cli data-section-id=\"114o5r6\" data-start=\"3637\" data-end=\"3658\"\u003eMain control unit\u003c\/li\u003e\n\u003cli data-section-id=\"z5pf33\" data-start=\"3659\" data-end=\"3706\"\u003e8 cryolipolysis applicators (various sizes)\u003c\/li\u003e\n\u003cli data-section-id=\"yu2wc4\" data-start=\"3707\" data-end=\"3758\"\u003eIntegrated cooling and water circulation system\u003c\/li\u003e\n\u003cli data-section-id=\"1ts3y7h\" data-start=\"3759\" data-end=\"3792\"\u003eIntelligent control interface\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SKIN MAX TECHNOLOGY","offers":[{"title":"Default Title","offer_id":42700392661090,"sku":null,"price":2900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/3426\/8258\/files\/360AngelMaxCryolipolysis.png?v=1775583374","url":"https:\/\/skinmaxtech.com\/products\/360-angel-max-cryolipolysis","provider":"SKIN MAX TECHNOLOGY MIAMI, FL","version":"1.0","type":"link"}